HC-11 Wireless Serial Module Remote 1000M With Antenna

New product

Supply voltage: 3.2V~5.5V. (If the module you want to work long hours in the emission state, it is recommended that when the supply voltage exceeds 4.5V threaded a 1N4007 diode to prevent module built-in LDO heated)

Default idle current: 16MA (In different working modes operating current is different)
Operating frequency range: 433.4-473.0MHz, up to 100 channels of communication

More details

₹ 340.00 tax excl.

  • Note: HC-11 cannot communicate with the HC-12, they work independently, in pairs

    Features:


    Supply voltage: 3.2V~5.5V. (If the module you want to work long hours in the emission state, it is recommended that when the supply voltage exceeds 4.5V threaded a 1N4007 diode to prevent module built-in LDO heated)
    Default address range (open field test): About 600m (maximum communication distance adjustable reach 1000m, the baud rate is 5000bps)
    Default idle current: 16MA (In different working modes operating current is different)
    Module dimensions: 27.8 x 14.4 x 4mm
    Operating frequency range: 433.4-473.0MHz, up to 100 channels of communication
    The maximum transmit power: 100mW (settable)
    Module support software upgrade
    Default factory settings: Mode FU3, baud rate is 9600bps, communication channels CH001 (433.4M)

    AT command set:
     
    Module parameters, AT command set
    AT command is used to set the parameters of the function module and switching modules need to exit the setting mode after setting to take effect. Meanwhile, modify the parameters and functions, power-down is not lost.
     
    Enter the command mode:

    The first entry mode - normal use (has the power) in the first 5-pin "SET" is set low;
    The second mode of entry - power, 5th pin "SET" again first set low on power.
    Both methods can make the module into AT command mode, release ("SET" pin is not connected low) to exit command mode. After the exit command mode, if you change the module function, the function will be cut to the appropriate state.
    The second way is fixed in serial format 9600, N, 1 into the AT.
     